TB388S analog time switches are an economical solution for applications requiring more than 20A and wide voltage (110-230 VAC). The unit is housed in a plastic enclosure. TB388S is suitable for a variety of applications, including: Billboard or Showcase Lighting, Air Conditioning or Commercial Refrigeration, Pumps/Motor/ Geyser/Fan Control, Hydroponic Systems, Wastewater Treatment Systems, Generator Exercising, Boilers / Heater Control, Pool & Spa, etc.
| Supply voltage | 230Vac, 50/60Hz other voltages on request |
| Switching capacity | Resistive load: 16 A / 250 V~ at cosφ=1 |
| Inductive load: 4 A / 250 V~ at cosφ=0.6 | |
| Number of switching segments | 48 |
| Time accuracy at 25 °C | ≤± 2 Sec./day (quartz) |
| Power reserve | – |
| Type of contact | changeover contact |
| Type of protection | IP 20 |
| Class of protection | II according to EN 60 730-1 |
| Permitted ambient temperature | -10 ~ +50 °C (non-icing) |
| Test approval | CE |
| Power consumption | 1.5 VA |
| Maximum recommended load (10,000 operations) | |
| Incandescent/halogen lamp load 230V | 1100 W |
| LED lamp 230V < 2 W | 20 W |
| LED lamp 230V > 2 W | 180 W |


LETOP performs maximum load test on timer switches